Guys, Good Day!

We have many jobs being sexecutados the control in these various jobs start job in datastage DW.

That this many licenses consumed, and our goal is to include in a job of control-m, a script that start date many stage, following the flow of execution, to reduce our consumption of licenses

How can we automate this process?

Thankful For Attention
Att.
Anderson


Top
   
 Post subject:
PostPosted: 23 Apr 2014 9:08 
Offline
Nouveau
Nouveau
User avatar

Joined: 19 Jun 2013 12:00
Posts: 36
well, first tell us, what kind of OS are u using?

you can create a batch file to run your processes and create just a job for every batch file.


Top
   
 Post subject:
PostPosted: 23 Apr 2014 9:53 
Offline
Nouveau
Nouveau
User avatar

Joined: 10 May 2013 12:00
Posts: 11
Carlos,
Thank you for your attention.

Both the station environment using RedHat Linux
Control Server OS-EM with RedHat Linux with Oracle database
DataStage server with Linux RedHat OS

Att
Anderson


Top
   
 Post subject:
PostPosted: 23 Apr 2014 10:13 
Offline
Nouveau
Nouveau
User avatar

Joined: 19 Jun 2013 12:00
Posts: 36
it is easy then... you can create batch scripts to run your datastage processes, it's easy to control a job execution on linux based OS whenever there is a error echo a static message (read this on control-M job so it can DO NOTOK and terminate), whenever the process end ok run the next until the last one; on the last one send another static message (read this on control-M so the job can DO OK) and done.

this is the way we (on the company i work) run our DWH processes with just a few control-M Jobs.


Top
   
PostPosted: 28 Apr 2015 11:45 
Offline
Nouveau
Nouveau
User avatar

Joined: 08 Jun 2007 12:00
Posts: 807
Location: Varese - Italy
Consider also the use of the Control Module for DataStage: you can define jobs in DataStage without run a script and with a direct connection to DataStage.


Top
   
Display posts from previous:  Sort by  
Post new topic  Reply to topic  [ 5 posts ] 

All times are UTC+02:00


Who is online

Users browsing this forum: No registered users and 1 guest


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
Powered by phpBB® Forum Software © phpBB Limited
The site created by Franck YOT. Images, logo, content and trademarks about Control-M products are property of BMC Software.
All the comments are property of their posters. Images, logo, content and design are © copyright by Scheduler-Usage.com. All Rights Reserved